Rectifier AR-800A-400Hz
High efficiency coefficient
Adjustable output
Phase loss and phase imbalance protection
Heavy duty design
Maximum repair time: 20 min
Designed to comply with RoHS and REACH requirements
Rectifier AR-800A with 400Hz input is designed for use on AC ground power units to supply 28V DC to aircrafts and helicopters. It is also can be used as a power unit of test benches, hangars and aircraft manufacturing plants.
The rectifier can be power supplied by any type of 400Hz 200V converter (50/60Hz based units also available):
– Diesel generators
– Static frequency converters
The rectifier is designed to supply 800 A continuous output and 2500 A soft engine start. The rectifier is available in mobile and stationary version.
Features:
- Low line current distortion
- High quality of output voltage
- High efficiency coefficient
- Low input harmonic distortion
- Output current high quality
- Adjustable output
- 800 A continuous output power
- 2500 A (adjustable) soft-start engine starting
- Phase loss and phase imbalance protection
- Heavy duty design
- Average pre-repair working time: 100 000 h
- Maximum repair time: 20 min
1. | Output parameters: | |
1.1 | Rated output voltage, V DC | 28 |
1.2 | Output voltage stabilization accuracy, V | ± 0,5 |
1.3 | Voltage regulation | 21-36 |
1.4 | Pulsation coefficient of output voltage, % | ≤ 7,4 |
1.5 | Rated output current, A | 800 |
1.6 | Current overloads, A | |
– 60 sec | 1800 | |
– 30 sec | 2100 | |
– 5 sec | 2500 | |
1.7 | Overall efficiency, % | ≥ 92 |
1.8 | Quantity of outputs | 1 |
1.9 | Crest factor | 1,414 ± 3% |
2. | Input parameters: | |
2.1 | Supply main rated voltage, V AC | 3×115\200V |
2.2 | Supply main voltage permitted deviation, % | ± 15 |
2.3 | Supply nominal frequency, Hz | 400 |
2.4 | Supply rated frequency deviation, Hz | ± 10 |
2.5 | THD, % | < 5 |
2.6 | Power factor | > 0,9 |
2.7 | Inrush current | no, soft start |
3. | Miscellaneous: | |
3.1 | Overall dimensions (stationary), W x H x D, mm | 660 х 625 х 660 |
3.2 | Weight, kg | ≤ 200 |
3.3 | Ingress protection | IP55 |
3.4 | Maximum ambient temperature, ºС | plus 45 |
3.5 | Minimal ambient temperature, ºС | minus 10 (minus 40 optionally) |
3.6 | MTBF | 100 000 hours |
3.7 | MTTR | max 20 minutes |
Portfolio
FCA-90M
FCA-90/AR-600M
AR-2×600
FCA-90М
FCA90/AR-2х600-М
FCA-90S
FCA-90S
FCA-90S, FCA-15
AR-400, FCA-63
FCA-100
FCA-63/AR-400, FCA-90S, FCA-120S
AR-400, FCA-90S
AR-400, FCA-90S, FCA-30
FCA-10-6S
FCA-90/АВ-1-600х28,5 (mobile)
FCA-90-12M (mobile)